Home > Knowledge > Content

Which parts should be checked during the daily maintenance of a small injection molding machine?

Oct 27, 2026

During long-term use, various components of a small injection molding machine --such as injection system, clamping mechanism, hydraulic or electrical system --are affected by temperature, pressure and mechanical movement. Regular maintenance helps ensure stable molding performance, reduces unplanned downtime, and extends the service life of key components.
As a supplier of small injection molding machines, we recommend customers develop maintenance plans based on equipment configuration, materials processed and frequency of use. The inspection shall be carried out in accordance with the specifications of the equipment. Maintenance requirements may vary from model to model. Please refer to the manufacturer's technical documentation for specific requirements.


I. Inspecting the Injection System
The injection system is responsible for plasticizing, measuring and injection molding of plastic raw materials, which is the key factor affecting the quality of injection molding products.
Check the barrel, screws, nozzle and associated connectors for abnormalities during daily inspection. After the operation of the machine, observe plastic melting stability of the molding and injection processes, and pay attention to the problems of abnormal noise, material leakage and uneven molding.
If you experience problems such as short range (incomplete filling), surface defects, or product weight fluctuations, consider factors such as raw material drying, temperature settings, injection parameters, and the overall condition of the equipment. Don't try to solve all problems by simply increasing the injection pressure.


II. Check the Clamping Mechanism
The clamping mechanism is responsible for closing the mold and providing the necessary clamping force injection process. Its operating condition directly affects the closing of the die and the molding quality of the product.
In maintenance process, the following should be noted:
1.Check whether there is any obvious damage or abnormal deformation of the press plate, tie bars and related structural parts.
2.Observe the closing and opening motions to make sure they are smooth and free of unusual vibrations or noises.
3. Check mold installation and fastening to ensure all fasteners remain secure.
4. Inspect lubrication points according to manufacturer's requirements to ensure that moving parts work properly.
If the mold does not close properly, the movement is irregular, or there is noticeable, abnormal noise, immediately stop work, investigate the cause. When the machine is running, do not enter the mold area for inspection.

 

III. Check hydraulic or transmission systems
Small injection molding machine can adopt hydraulic, servo hydraulic or all-electric drive system. Maintenance tasks should be determined according to the specific type of equipment. For hydraulic equipment, check the level and condition of hydraulic oil, check pipes and fittings for leaks, and monitor equipment for abnormal noise or temperature rise during operation.
For pureelectric equipment, the servo drives, motors, transmission mechanisms and associated connections should be inspected in accordance with manufacturer's manual; hydraulic system maintenance requirements should not be applied to pureelectric equipment.
If liquid contamination, leakage or drive malfunctions is detected, equipment maintenance procedures shall be followed. Any task involving the removal of hydraulic lines or the repair of transmission systems must be carried out in accordance with prescribed procedures for closing, decompression and energy isolation.

 

IV. INTRODUCTION Check Heating Systems and temperature control
heating system are responsible for bringing plastic materials to a state suitable for processing. Temperature irregularities can lead to uneven plasticization, degradation of materials or fluctuations in product quality.
During routine maintenance, verify that the temperature readings in each heating zone on the drum are normal and check heating bands, temperature sensors and associated wiring for signs of loosening, damage or abnormal heat.
If there is a significant deviation between the actual temperature and the set temperature, or if the device triggers a continuous temperature alarms, inspect the sensors, heating elements and control system. Don't arbitrarily raise the setting temperature until the underlying cause has been identified.
For thermosensitive plastics, temperature and residence time must be strictly controlled according to the material's specific processing requirements.

info-730-730

V. Inspection of electrical systems and Safety Devices
The electrical system controls equipment control, parameter adjustment and mechanical movement coordination. The periodic inspection shall include operation panels, alarm notifications, wiring and equipment grounding.
In addition, ensure that emergency stop buttons, safety gate interlocks and other protective devices operate as designed. Safety devices must never be bypassed, removed or disabled.
If there are frequent alarms, control panel anomalies or equipment movements that do not comply with the order, they should be handled by qualified personnel. Before opening the cabinet or repairing electrical components, ensure that the power supply is disconnected and that the prescribed energy isolation procedures are followed.
VI. INTRODUCTION Check Lubrication Systems and moving parts
For small injection molding machines, components such as guide rails, connecting rods, sliding surfaces and other moving mechanisms must be lubricated and inspected in accordance with the manufacturer's specifications. During maintenance, ensure that the type of lubricant or grease used conforms to the specifications of the equipment. Make sure all lubrication points are supplied properly and remove any plastic debris or dust that could prevent components from moving.
If the moving parts are found to have adhesions, abrasions, gaps or unusual noises, they should be investigated immediately. More lubricating oil, the better excessive lubrication can lead to pollution or interfere with the equipment's operation.

 

VII. Check cooling systems and Surrounding Environment
The cooling system regulates the temperature of mold and related components, which directly influences mold forming cycle and product quality.
During routine inspection, make sure all cooling lines are connected correctly, water flows smoothly, and no leaks or blockages occur in pipes or fittings. For equipment using alternative cooling methods, the specific maintenance requirements of these systems should be followed.
Also, keep the area around the device clean and tidy. Ensure adequate ventilation, operation and maintenance space. Clean up spilled raw materials and waste in a timely manner to prevent them from entering mobile machinery or obstructing human activities.

 

Frequently Asked Questions 
Q1: Does a small injection molding machine require routine maintenance?
Basic daily checks are recommended,such as looking at the workings of the machine, looking for noticeable leaks or unusual noises, and tidying up the surrounding area. Lubrication, deep cleaning and component overhauls shall be performed at intervals specified by the manufacturer.
Question 2: If a small injection molding machine produces a "short lens" (incomplete filling), must the injection system be malfunctioning?
Not necessarily. Short-range shots can be caused by a variety of factors, including injection parameters, raw material conditions, mold venting, gate design or the overall state of the equipment. You should investigate each potential cause according to the specific product and production conditions.

Send Inquiry